I/O Commands
Input/Output Management +WIOM
©Restricted
Page: 75 / 158
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 4 August 23, 2007
22.1.3 Parameters and Defined Values
<Gpiold>: GPIO Index
range: 1-44
<GpioDir>: I/O direction or configuration
0 input (default value)
1 output
2 used by a feature (only in read mode)
<GpioVal>: I/O state
0 <Gpiold> is reset/low
1 <Gpiold> is set/high
22.1.4 Parameter Storage
The <GpioDir> and <GpioVal> parameters are stored in EEPROM without using the
AT&W command.