Bits 5, 2..0 – WDP3..0: Watchdog Timer Prescaler 3, 2, 1, and 0
The WDP3..0 bits determine the Watchdog Timer prescaling when the Watchdog Timer
is enabled. The different prescaling values and their corresponding Timeout Periods are
shown in Table 21.
Table 21. Watchdog Timer Prescale Select
WDP3 WDP2 WDP1 WDP0
Number of WDT Oscillator
Cycles
Typical Time-out at
V
CC
= 5.0V
0000 2K cycles 16 ms
0001 4K cycles 32 ms
0010 8K cycles 64 ms
0011 16K cycles 0.125 s
0100 32K cycles 0.25 s
0101 64K cycles 0.5 s
0110 128K cycles 1.0 s
0111 256K cycles 2.0 s
1000 512K cycles 4.0 s
1001 1024K cycles 8.0 s
1010
Reserved
1011
1100
1101
1110
1111