DS60
3 of 4 102299
NOTES:
1. All voltages are referenced to ground, unless otherwise specified.
2. Solder according to IPC standards.
3. Specified for V
O
sourcing 1.0 µA (max).
4. Thermometer error (expressed in °C) is the difference between [V
O
(T) - 424]/6.25 and the DS60 case
temperature at V
DD
= 3.0V, thus taking into account sensor error, DC offset error, sensor amplifier
gain variations, and amplifier nonlinearity.
5. Nonlinearity is the maximum deviation of an ideal linear slope for a given DS60.
6. This is the typical drift following 3 consecutive passes through a vapor phase.
TYPICAL DS60 THERMOMETER ERROR Figure 1
TBD