Note: 1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
Input Test Waveforms and
Measurement Levels
t
R
, t
F
< 3 ns (10% to 90%)
Output Test Load
DC Characteristics
Symbol Parameter Condition Min Typ Max Units
I
LI
Input Load Current V
IN
= -0.1V to V
CC
+ 1V 10 µA
I
LO
Output Leakage
Current
V
OUT
= -0.1V to V
CC
+ 0.1V 10 µA
I
CC
Power Supply
Current, Standby
V
CC
= Max,
V
IN
= Max,
Outputs Open
C-7, -10
Com. 125 180 mA
Ind., Mil. 135 190 mA
C-15
Com. 125 180 mA
Ind., Mil. 135 190 mA
CL-15
Com. 0.12 1 mA
Ind., Mil. 0.15 2 mA
I
OS
(1)
Output Short
Circuit Current
V
OUT
= 0.5V -120 mA
V
IL
Input Low Voltage 4.5 ≤ V
CC
≤ 5.5V -0.6 0.8 V
V
IH
Input High Voltage 2.0 V
CC
+ 0.75 V
V
OL
Output Low
Voltage
V
IN
= V
IH
or V
IL
,
V
CC
= Min
I
OL
= 16 mA Com., Ind. 0.5 V
I
OL
= 12 mA Mil. 0.5 V
I
OL
= 24 mA Com. 0.8 V
V
OH
Output High
Voltage
V
IN
= V
IH
or V
IL
,
V
CC
= Min
I
OH
= -4.0 mA 2.4 V
VCC