Rainbow-electronics AT83C26 Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 77
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
22
7511B–SCR–10/05
AT83C26
The DC/DCB sensitivity to any overflow current can be modified (20%) by using the ICCADJB bit
(DC/DCB register).
Initialization Procedure for DC/DC B converter
The initialization procedure is described in flow chart:
Select the DC/DC B level by means of bits VDCB[1:0] in DCDCB register,
Set bits DEMBOOSTB[1:0] in INTERFACEB register following the current level control
wanted.
Monitor VDCB_OK bit in DCDCB register in order to know when the DC/DC B Converter is
ready
Figure 10. DC/DC B Converter Initialization Procedure
Increment of DEMBOOSTB[1:0] bits increases at the same time the current overflow level in the
same proportion as the startup current. So once the DC/DC B converter is ready it advised to
decrement the DEMBOOSTB[1:0] bits to restore the overflow current to its normal or desired
value.
DEMBOOSTB[1:0]=[0:0]
VDCB_OK=1
Set Time-out to 3 ms
Time-out
Expired
DEMBOOSTB[1:0]
is at Maximum?
DC/DC B Converter
Initialization Failure
END
END
(ready to start LDO)
Decrement
DEMBOOSTB[1:0]
to adjust the
current overflow
Increment
DEMBOOSTB[1:0]
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 76 77

Commentaires sur ces manuels

Pas de commentaire