GENERAL DESCRIPTION
The DS2756 high-precision battery fuel gauge is a
data-acquisition and information-storage device
tailored for cost-sensitive and space-constrained 1-
cell Li+/polymer battery-pack applications. The
DS2756 provides the key hardware components
required to accurately estimate remaining capacity by
integrating low-power, precision measurements of
temperature, voltage, current, and current
accumulation, as well as nonvolatile (NV) data
storage, into the small footprint of a 3.0mm x 4.4mm
8-pin TSSOP package.
Through its 1-WireÒ interface, the DS2756 gives the
host system read/write access to status and control
registers, instrumentation registers, and general-
purpose data storage. Each device has a unique
factory-programmed 64-bit net address that allows it
to be individually addressed by the host system,
supporting multibattery operation.
TYPICAL OPERATING CIRCUIT
Protector
DS2756
DQ
PIO
VIN
VDD
SNS
IS2
IS1
VSS
PACK+
INT
PACK-
150
150
1K
150
0.020
0.1µF
0.1µF
5.1V
5.1V5.1V
DATA
FEATURES
§ Programmable Suspend Mode
§ Accurate Current Accumulation
- 2% ±4mV over ±64mV Input Range
- 2% ±200mA over ±3.2A with 20mW Sense
§ Current Measurement
- 9-Bit Snapshot Measurement
- 12-Bit Average Updated Every 88ms
- 15-Bit Average Updated Every 2.8s
§ Voltage Measurement
- 9-Bit Snapshot Measurement
- 10-Bit Average Updated Every 4ms
§ Temperature Measurement
- 10-Bit with 0.125°C Resolution
§ Snapshot mode allows instantaneous power
measurement
§ Host Alerted When Accumulated Current or
Temperature Exceeds Programmable Limits
§ 96 Bytes of Lockable EEPROM
§ 8 Bytes of General-Purpose SRAM
§ Dallas 1-Wire Interface with Unique 64-Bit
Address and Standard or Overdrive Timing
§ 3mm Dimension of 8-Pin TSSOP Package
Allows Mounting on Side of Thin Prismatic
Li+ and Li+/Polymer Cells
ORDERING INFORMATION
PART TEMP RANGE PIN-PACKAGE
DS2756E+ -20°C to +70°C 8 TSSOP
DS2756E+T&R -20°C to +70°C
DS2756E+ on
Tape-and-Reel
+ Denotes lead-free package.
PIN CONFIGURATION
V
IN
DQ
SNS
IS2
PIO
1
2
2
1 8
7
6
5
V
SS
2
3
V
DD
4
IS1
DS2756E
TSSOP Packa
g
e
DS2756
High-Accuracy Battery Fuel Gauge
with Programmable Suspend Mode
www.maxim-ic.com
1-Wire is a registered trademark of Dallas Semiconductor.
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1

1 of 26 050806 Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revision

Page 2 - 2 of 26

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 10 of 26 PROGRAMMABLE I/O The PIO pin can be configured as a general purpose

Page 3 - 3 of 26

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 11 of 26 Table 1. PIO/DQ Pin Function REGISTER BIT SETTING PIO/DQ PIN FUNCT

Page 4 - DETAILED DESCRIPTION

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 12 of 26 ALARM COMPARATORS AND INTERRUPT THRESHOLDS Alarm interrupt thresho

Page 5 - DETAILED PIN DESCRIPTION

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 13 of 26 Figure 11. Alarm Interrupt Threshold Register Formats Current Accu

Page 6 - Current Measurement

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 14 of 26 Figure 12. Alarm And Suspend Mode Operating Diagram IEInterrupt En

Page 7 - CURRENT ACCUMULATION

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 15 of 26 SNAPSHOT MODE Measurement of the current and voltage can be synchro

Page 8 - ACCUMULATION BIAS

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 16 of 26 MEMORY The DS2756 has a 256-byte linear address space with register

Page 9

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 17 of 26 Table 2. Memory Map ADDRESS (HEX) DESCRIPTION READ/WRITE 00 Res

Page 10 - INTERRUPT SIGNALING

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 18 of 26 Table 3. SUMMARY OF SUSPEND MODES PIE1 PIE0 SAMPLE RATE WHILE IN S

Page 11 - SUSPEND THRESHOLDS

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 19 of 26 EEC—EEPROM Copy Flag. A 1 in this read-only bit indicates that a Co

Page 12 - 12 of 26

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 2 of 26 ABSOLUTE MAXIMUM RATINGS Voltage on PIO Pin, Relative to VSS -0.

Page 13

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 20 of 26 1-Wire BUS SYSTEM The 1-Wire bus is a system that has a single bus

Page 14 - 14 of 26

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 21 of 26 later. If the bus is left low for more than 120ms, slave devices on

Page 15 - SNAPSHOT MODE

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 22 of 26 the function command and wait for a reset pulse. This command can b

Page 16 - 16 of 26

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 23 of 26 Table 4. FUNCTION COMMANDS COMMAND DESCRIPTION COMMAND PROTOCOL BU

Page 17 - Table 2. Memory Map

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 24 of 26 Figure 21. Net Address Command Flow Chart YESNOYESYESYESYESNOMASTER

Page 18 - EEPROM REGISTER

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 25 of 26 I/O SIGNALING The 1-Wire bus requires strict signaling protocols to

Page 19 - SPECIAL FEATURE REGISTER

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 26 of 26 Figure 23. 1-Wire Write And Read Time Slots

Page 20

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 3 of 26 Period Undervoltage Detect VUV 2.4V < VDD < 5.5V (Note 1) 2.

Page 21 - § Transaction/Data

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 4 of 26 DETAILED DESCRIPTION The DS2756 performs temperature, voltage, and

Page 22 - FUNCTION COMMANDS

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 5 of 26 Figure 2. Functional Diagram 1-WIRE INTERFACE AND ROM IDVOLTAGEREFE

Page 23 - Table 4. FUNCTION COMMANDS

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 6 of 26 POWER MODES The DS2756 has three power modes: Active, Suspend and Sl

Page 24 - 24 of 26

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 7 of 26 error is introduced into both the Average Current and Accumulated Cu

Page 25

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 8 of 26 command targeting the ACR register address. A write to the ACR resul

Page 26 - 26 of 26

DS2756: High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode 9 of 26 Figure 6. Accumulation Bias Register Format Address 33h S 2

Commentaires sur ces manuels