DS1390/DS1391/DS1392/DS1393
Low-Voltage SPI/3-Wire RTCs with
Trickle Charger
_____________________________________________________________________ 3
RECOMMENDED DC OPERATING CONDITIONS (continued)
(V
CC
= V
CC(MIN)
to V
CC(MAX)
, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at nominal supply voltage and T
A
= +25°C,
unless otherwise noted.) (Note 1)
SYMBOL
MIN TYP MAX
115
175
-3 80 125
V
CC
Standby Current
(Note 11)
I
CCS
-18 60 100
µA
V
BACKUP
Leakage Current
(V
BACKUP
= 3.7V,
V
CC
= V
CC(MAX)
)
I
BACKUPLKG
DC ELECTRICAL CHARACTERISTICS
(V
CC
= 0V, V
BACKUP
= 3.7V, T
A
= -40°C to +85°C, unless otherwise noted.) (Note 1)
SYMBOL
MIN TYP MAX
V
BACKUP
Current OSC On,
SQW Off
I
BACKUP1
500 1000
nA
V
BACKUP
Current OSC On,
SQW On (32kHz)
I
BACKUP2
600 1150
nA
V
BACKUP
Current OSC On,
SQW On, V
BACKUP
= 3.0V,
T
A
= +25°C
I
BACKUP3
600 1000
nA
V
BACKUP
Current, OSC Off
(Data Retention)
I
BACKUPDR
AC ELECTRICAL CHARACTERISTICS—SPI INTERFACE
(V
CC
= V
CC(MIN)
to V
CC(MAX)
, T
A
= -40°C to +85°C, unless otherwise noted.) (Note 1)
SYMBOL
MIN TYP MAX
2.7V ≤ V
CC
≤ 5.5V 4
SCLK Frequency (Note 13) f
SCLK
1.71V ≤ V
CC
≤ 1.89V 1
Data to SCLK Setup t
DC
(Notes 13, 14) 30 ns
SCLK to Data Hold t
CDH
(Notes 13, 14) 30 ns
2.7V ≤ V
CC
≤ 5.5V 80
SCLK to Data Valid
(Notes 13, 14, 15)
t
CDD
1.71V ≤ V
CC
≤ 1.89V 160
ns
2.7V ≤ V
CC
≤. 5.5V
110
SCLK Low Time (Note 13) t
CL
1.71V ≤ V
CC
≤ 1.89V
400
110
SCLK High Time (Note 13) t
CH
1.71V ≤ V
CC
≤ 1.89V
400
ns
SCLK Rise and Fall t
R
, t
F
200 ns
CS to SCLK Setup (Note 13) t
CC
400
ns
SCLK to CS Hold (Note 13) t
CCH
100
400
CS Inactive Time (Note 13) t
CWH
1.71V ≤ V
CC
≤ 1.89V
500
ns
CS to Output High Impedance t
CDZ
(Notes 13, 14) 40 ns
Commentaires sur ces manuels